Akım Sensörleri
- Komponent
- 2,744
- Marka
- 52
Komponentler
2,744 sonuç · Sayfa 16/55| Parça No | Üretici | Part Status | Operating Temperature | Mounting Type | Package / Case | Polarization | Frequency | Sensitivity | Number of Channels | Supplier Device Package | Response Time | Output | Voltage - Supply | Current - Supply (Max) | Accuracy | Sensor Type | Linearity | For Measuring | Current - Sensing | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CKSR 25-NP KIT 3P
SENSOR CURRENT FLUX AC/DC |
LEM USA, Inc. | Obsolete | -40°C ~ 85°C (TA) | Through Hole | Module | — | 300kHz | 25mV/A | 1 | — | 300ns | Ratiometric, Voltage | 4.75V ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±0.1% | AC/DC | 25A | — |
|
CKSR 25-NP/SP2
SENSOR CURRENT FLUX AC/DC |
LEM USA, Inc. | Obsolete | -40°C ~ 85°C (TA) | Through Hole | Module | — | 300kHz | 25mV/A | 1 | — | 300ns | Ratiometric, Voltage | 4.75V ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±0.1% | AC/DC | 25A | — |
|
CKSR 50-NP
SENSOR CURRENT FLUX 50A AC/DC |
LEM USA, Inc. | Active | -40°C ~ 105°C | Through Hole | Module | Bidirectional | 300kHz | 12.5mV/A | 1 | — | 0.3µs | Ratiometric, Voltage | 4.75 ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±1% | AC/DC | 50A | — |
|
CKSR 50-NP KIT 3P
SENSOR CURRENT FLUX AC/DC |
LEM USA, Inc. | Obsolete | -40°C ~ 85°C (TA) | Through Hole | Module | — | 300kHz | 12.5mV/A | 1 | — | 300ns | Ratiometric, Voltage | 4.75V ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±0.1% | AC/DC | 50A | — |
|
CKSR 6-NP
SENSOR CURRENT FLUX 6A AC/DC |
LEM USA, Inc. | Active | -40°C ~ 105°C | Through Hole | Module | Bidirectional | 300kHz | 104.2mV/A | 1 | — | 0.3µs | Ratiometric, Voltage | 4.75V ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±1% | AC/DC | 6A | — |
|
CKSR 6-NP KIT 3P
SENSOR CURRENT FLUX AC/DC |
LEM USA, Inc. | Obsolete | -40°C ~ 85°C (TA) | Through Hole | Module | — | 300kHz | 104.2mV/A | 1 | — | 300ns | Ratiometric, Voltage | 4.75V ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±0.1% | AC/DC | 6A | — |
|
CKSR 75-NP
SENSOR CURRENT FLUX 75A AC/DC |
LEM USA, Inc. | Active | -40°C ~ 105°C | Through Hole | Module | Bidirectional | 300kHz | 12.5mV/A | 1 | — | 0.3µs | Ratiometric, Voltage | 4.75 ~ 5.25V | 20mA | ±0.8% | Flux Gate, Closed Loop | ±1% | AC/DC | 75A | — |
|
CPC-1000-27-BP2
DC-AC CURRENT PROBE, CLIP-ON, 1K |
GMW Associates | Active | -40°C ~ 100°C | Free Hanging | Box | Bidirectional | DC ~ 75kHz | — | 1 | — | 10µs | Ratiometric, ±2V | 3.5V ~ 5.5V | 85mA | 1% | Open Loop | ±0.2% | AC/DC | 1000A | — |
|
CPC-2000-27-BP2
DC-AC CURRENT PROBE, CLIP-ON, 2K |
GMW Associates | Active | -40°C ~ 100°C | Free Hanging | Box | Bidirectional | DC ~ 75kHz | — | 1 | — | 10µs | Ratiometric, ±2V | 3.5V ~ 5.5V | 85mA | 1% | Open Loop | ±0.2% | AC/DC | 2000A | — |
|
CPC-250-27-BP2
DC-AC CURRENT PROBE, CLIP-ON, 25 |
GMW Associates | Active | -40°C ~ 100°C | Free Hanging | Box | Bidirectional | DC ~ 75kHz | — | 1 | — | 10µs | Ratiometric, ±2V | 3.5V ~ 5.5V | 85mA | 1% | Open Loop | ±0.2% | AC/DC | 250A | — |
|
CPC-500-27-BP2
DC-AC CURRENT PROBE, CLIP-ON, 50 |
GMW Associates | Active | -40°C ~ 100°C | Free Hanging | Box | Bidirectional | DC ~ 75kHz | — | 1 | — | 10µs | Ratiometric, ±2V | 3.5V ~ 5.5V | 85mA | 1% | Open Loop | ±0.2% | AC/DC | 500A | — |
|
CPCO-1000-160-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-160-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-160-MA
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-160-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-160-SE
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-77-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-77-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-77-MA
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-77-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-1000-77-SE
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 1000A | — |
|
CPCO-12000-160-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-160-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-160-MA
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-160-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-160-SE
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-77-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-77-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-77-MA
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-77-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-12000-77-SE
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 12000A | — |
|
CPCO-16000-160-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 16000A | — |
|
CPCO-16000-160-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 16000A | — |
|
CPCO-16000-160-MA
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 16000A | — |
|
CPCO-16000-160-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 16000A | — |
|
CPCO-16000-160-SE
DC-AC CURRENT PROBE, CLAMP-ON, 1 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 16000A | — |
|
CPCO-2000-160-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-160-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-160-MA
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-160-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-160-SE
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-77-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-77-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-77-MA
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-77-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-2000-77-SE
DC-AC CURRENT PROBE, CLAMP-ON, 2 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 0V ~ 10V | 11V ~ 31V | 47mA | 1% | Open Loop | ±0.5% | AC/DC | 2000A | — |
|
CPCO-4000-160-BP10
DC-AC CURRENT PROBE, CLAMP-ON, 4 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±10V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 4000A | — |
|
CPCO-4000-160-BP5
DC-AC CURRENT PROBE, CLAMP-ON, 4 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, ±5V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 4000A | — |
|
CPCO-4000-160-MA
DC-AC CURRENT PROBE, CLAMP-ON, 4 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 10µs | Ratiometric, 4mA ~ 20mA | 11V ~ 26V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 4000A | — |
|
CPCO-4000-160-RMS
DC-AC CURRENT PROBE, CLAMP-ON, 4 |
GMW Associates | Active | -40°C ~ 100°C | Panel Mount | Box | Bidirectional | DC ~ 40kHz | — | 1 | — | 1s | Ratiometric, 0V ~ 3V | 11V ~ 31V | 80mA | 1% | Open Loop | ±0.5% | AC/DC | 4000A | — |