Akım Sensörleri
- Komponent
- 2,744
- Marka
- 52
Komponentler
2,744 sonuç · Sayfa 1/55| Parça No | Üretici | Part Status | Operating Temperature | Mounting Type | Package / Case | Polarization | Frequency | Sensitivity | Number of Channels | Supplier Device Package | Response Time | Output | Voltage - Supply | Current - Supply (Max) | Accuracy | Sensor Type | Linearity | For Measuring | Current - Sensing | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1510390000
CONDITIONER SIGNAL RAIL MNT |
Weidmuller | Active | -25°C ~ 60°C | DIN Rail | Box | Bidirectional | — | — | 1 | — | 300ms | Relay, SPDT | 16.8V ~ 31.2V | — | ±1.5% | Current Switch | — | AC/DC | 60A | — |
|
1510470000
CONDITIONER SIGNAL RAIL MNT |
Weidmuller | Active | -25°C ~ 60°C | DIN Rail | Module | Bidirectional | — | — | 1 | — | — | Ratiometric, Voltage and Current | 18V ~ 30V | — | — | — | — | AC/DC | 10A | — |
|
1510540000
ACT20P-CMT-30-AO-RC-S |
Weidmuller | Active | -25°C ~ 60°C | DIN Rail | Module | Bidirectional | 15Hz ~ 700Hz | — | 1 | — | 220ms | Ratiometric, Voltage and Current | 16.8V ~ 31.2V | 20mA | ±0.75% | Current Switch | — | AC/DC | 30A | — |
|
20310200101
SENSOR CURRENT HALL 200A AC |
HARTING | Active | -40°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V | 20mA | ±0.8% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 200A | — |
|
20310200102
SENSOR CURRENT HALL 200A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 12V ~ 15V | 20mA | ±0.8% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 200A | — |
|
20310200103
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310200202
CURRENT SENSOR 200A WITH CLAMP T |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310200301
CURRENT SENSOR 200A SMALL |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310200304
CURRENT SENSOR |
HARTING | Last Time Buy | -40°C ~ 85°C (TA) | Panel Mount | Module, Single Pass Through | — | 0Hz ~ 100kHz | — | 1 | — | 1µs | — | 12V ~ 15V | 117mA | ±0.5% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 200A | — |
|
20310207101
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310300101
SENSOR CURRENT HALL 300A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V | 25mA | ±0.5% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 300A | — |
|
20310300102
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310300201
CURRENT SENSOR 300A WITH CLAMP T |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310300301
CURRENT SENSOR 300A SMALL |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310500101
SENSOR CURRENT HALL 500A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V ~ 24V | 24mA | ±0.6% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 500A | — |
|
20310500103
HCS 500A W.D-SUB, 1000A HOUS., S |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310500201
CURRENT SENSOR 500A WITH CLAMP T |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310508101
CURRENT SENSOR RAILWAY 500A WITH |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310508102
HCSR 500A M12 RAILWAY M. FUSS |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310508201
CURRENT SENSOR RAILWAY 500A WITH |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310509101
SENSOR CURRENT HALL 500A AC |
HARTING | Active | -40°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 1µs | Ratiometric, Voltage | 15V ~ 24V | 35mA | ±1% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 500A | — |
|
20310509103
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20310509201
CURRENT SENSOR RAILWAY 500A WITH |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311000101
SENSOR CURRENT HALL 1000A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V ~ 24V | 28mA | ±0.4% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 1000A | — |
|
20311000201
CURRENT SENSOR 1000A WITH CLAMP |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311008101
CURRENT SENSOR RAILWAY 1000A WIT |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311008102
CURRENT SENSOR |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311008103
HCSR 1000A D-SUB CONNECTOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311008201
CURRENT SENSOR RAILWAY 1000A WIT |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311009101
SENSOR CURRENT HALL 1000A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V ~ 24V | 28mA | ±0.4% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 1000A | — |
|
20311009103
HCSR1000 W.120MM CABLE + 3A HPR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311009106
CURRENT SENSOR |
HARTING | Last Time Buy | -40°C ~ 85°C (TA) | Panel Mount | Module, Single Pass Through | — | 0Hz ~ 100kHz | — | 1 | — | 1µs | — | 15V ~ 24V | 228mA | ±0.4% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 1000A | — |
|
20311009201
CURRENT SENSOR RAILWAY 1000A WIT |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311308101
CURRENT SENSOR 1300A RAILW. W.FE |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20311400101
CURRENT SENSOR |
HARTING | Last Time Buy | 5°C ~ 60°C (TA) | Panel Mount | Module, Single Pass Through | — | 0Hz ~ 100kHz | — | 1 | — | 1µs | — | 15V ~ 24V | 492mA | ±0.4% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 1400A | — |
|
20312000101
SENSOR CURRENT HALL 2000A AC |
HARTING | Active | -40°C ~ 85°C | Panel Mount | Module, Single Pass Through | Bidirectional | 100kHz | — | 1 | — | 1µs | Ratiometric, Voltage | 15V ~ 24V | 33mA | ±0.3% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 2000A | — |
|
20312000103
CURRENT SENSOR |
HARTING | Active | -20°C ~ 85°C (TA) | Panel Mount | Module, Single Pass Through | — | 0Hz ~ 100kHz | — | 1 | — | 1µs | — | 15V ~ 24V | 520mA | ±0.3% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 2000A | — |
|
20312000201
CURRENT SENSOR 2000A WITH CLAMP |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20312009101
SENSOR CURRENT HALL 2000A AC |
HARTING | Active | -40°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 1µs | Ratiometric, Voltage | 15V | 33mA | ±0.3% | Hall Effect, Closed Loop | ±0.1% | AC/DC | 2000A | — |
|
20312009106
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20312009201
CURRENT SENSOR RAILWAY 2000A WIT |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20312500101
CURRENT SENSOR |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20314000101
CURRENT TRANSFORMER 142 X 45MM, |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20314000102
SPARE PARTS TRANSFORMERS F 20314 |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20314000103
SPARE PARTS TRANSFORMERS F 20314 |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20314000201
PRIMARSCHIENENBEFESTIGUNG LANG F |
HARTING | Last Time Buy | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20320017101
AC CURRENT TRANSFORMER 10A |
HARTING | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
20320100101
CURRENT SENSOR HAN OPEN LOOP 100 |
HARTING | Active | -25°C ~ 85°C (TA) | Chassis Mount | — | — | DC ~ 50kHz | — | — | — | — | — | — | — | — | Current Sensor | — | AC/DC | 100A | — |
|
20320300101
CURRENT SENSOR HAN OPEN LOOP 300 |
HARTING | Active | -25°C ~ 85°C (TA) | Chassis Mount | — | — | DC ~ 50kHz | — | — | — | — | — | — | — | — | Current Sensor | — | AC/DC | 300A | — |
|
20320500101
CURRENT SENSOR HAN OPEN LOOP 500 |
HARTING | Active | -25°C ~ 85°C (TA) | Chassis Mount | — | — | DC ~ 50kHz | — | — | — | — | — | — | — | — | Current Sensor | — | AC/DC | 500A | — |