Gaz Sensörleri
- Komponent
- 757
- Marka
- 29
Komponentler
757 sonuç · Sayfa 8/16| Parça No | Üretici | Part Status | Operating Temperature | Current - Supply | Type | Output | Voltage - Supply | Accuracy | Oxygen Range | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|
|
IR32BC
SERIES 3, 19MM 0-5%/100% HC IR S |
Amphenol | Active | -20°C ~ 55°C (TA) | 60mA | Hydrocarbons, Methane | — | 3V ~ 5V | — | 300 mbar ~ 1300 mbar | — |
|
IR33BC
19MM 0-5%/100% BROADBAND HC IR S |
Amphenol | Active | -20°C ~ 55°C (TA) | 60mA | Hydrocarbons, Methane | — | 3V ~ 5V | — | 300 mbar ~ 1300 mbar | — |
|
IR601/1
IR SENSOR HEAD FOR 0-5%CO2 - M20 |
Amphenol | Active | -20°C ~ 60°C | 60mA | Carbon Dioxide (CO2) | Voltage | 5V | — | — | — |
|
IR601/2
IR SENSOR HEAD FOR 0-5%CO2 - 1/2 |
Amphenol | Active | -20°C ~ 60°C | 60mA | Carbon Dioxide (CO2) | Voltage | 5V | — | — | — |
|
IR601/3
IR SENSOR HEAD FOR 0-5%CO2 - 3/4 |
Amphenol | Active | -20°C ~ 60°C | 60mA | Carbon Dioxide (CO2) | Voltage | 5V | — | — | — |
|
IR602/1
IR SENSOR HEAD FOR 0-5%/100% HC |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR602/2
IR SENSOR HEAD FOR 0-5%/100% HC |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR602/3
IR SENSOR HEAD FOR 0-5%/100% HC |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR603/1
IR SENSOR HEAD FOR 0-5%/100% BRO |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR603/2
IR SENSOR HEAD FOR 0-5%/100% BRO |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR603/3
IR SENSOR HEAD FOR 0-5%/100% BRO |
Amphenol | Active | -20°C ~ 60°C | 60mA | Hydrocarbons | Voltage | 5V | — | — | — |
|
IR604/1
IR SENSOR HEAD FOR 0-100% LEL AC |
Amphenol | Obsolete | -20°C ~ 60°C | 60mA | Acetylene | Voltage | 5V | — | — | — |
|
IR604/2
IR SENSOR HEAD FOR 0-100% LEL AC |
Amphenol | Obsolete | -20°C ~ 60°C | 60mA | Acetylene | Voltage | 5V | — | — | — |
|
IR604/3
IR SENSOR HEAD FOR 0-100% LEL AC |
Amphenol | Obsolete | -20°C ~ 60°C | 60mA | Acetylene | Voltage | 5V | — | — | — |
|
KGZ-10SP-5PIN
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ-10SP-5PIN REV1
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ-NGL
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ-NGL-096
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ-NGL-370-REV2
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ-NGL-F
SENSOR OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ10
SENSOR OXYGEN 4.35V 40UA |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | — | Oxygen | 45mV, 64mV, 85mV | 4.35V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ10-5PIN
SENSOR OXYGEN 4.35V 40UA |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | — | Oxygen | 45mV, 64mV, 85mV | 4V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ10-SP
SENSOR OXYGEN 4.35V 40UA |
WEC | Obsolete | 700°C | — | Oxygen | 45mV, 64mV, 85mV | 4.35V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ11
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ12
KGZ-12 HIGH-ACCURACY OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | 40mA | Oxygen | Voltage | 4V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ12DITT
KGZ-12 HIGH-ACCURACY OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | 40mA | Oxygen | Voltage | 4V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ12DITT4V
KGZ-12 HIGH-ACCURACY OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | 40mA | Oxygen | Voltage | 4V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ12DITT4V-150
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ12DITT5V
KGZ-12 HIGH-ACCURACY OXYGEN |
Honeywell Sensing and Productivity Solutions | Obsolete | 700°C | 40mA | Oxygen | Voltage | 4V | < 5 mbar | 2 mbar ~ 3 bar | — |
|
KGZ21
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZ50
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZBL100
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
KGZBL50
SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
MBE60-024
TRANDUCER CO 3ME/F 10MV PPM |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MBF6G-004
TRANDUCER CO 3MF/F 0.1MV PPM |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MCH60-014
TRANDUCER H2S 3MH 1MV/PPM O/P |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MCH60-024
TRANDUCER H2S 3MH 10MV/PPM O/P |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MDF60-014
TRANSDUCER SO2 3MSF 1MV/PPM |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MEE60-004
TRANDUCER H2 3MHYE |
City Technology | Obsolete | — | — | — | — | — | — | — | — |
|
MF010-0-LC1
SENSOR OXYGEN 24V 500MA |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 250 mbar | — |
|
MF010-0-LC2
SENSOR OXYGEN 24V 500MA |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 1000 mbar | — |
|
MF010-0-LC3
SENSOR OXYGEN 24V 500MA |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 4mA ~ 20mA | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 250 mbar | — |
|
MF010-0-LC4
SENSOR OXYGEN 24V 500MA |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 4mA ~ 20mA | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 1000 mbar | — |
|
MF010-0-LC4-200
SENSOR GAUGE |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — |
|
MF010-1-LC1
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 250 mbar | — |
|
MF010-1-LC2
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 1000 mbar | — |
|
MF010-1-LC3
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 4mA ~ 20mA | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 250 mbar | — |
|
MF010-1-LC4
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 4mA ~ 20mA | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 1000 mbar | — |
|
MF010-2-LC1
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 250 mbar | — |
|
MF010-2-LC2
MF010 LOW TEMP OXYGEN SENSOR |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 50°C | 500mA | Oxygen | 0 V ~ 10 V | 22.8V ~ 25.2V | ±2% | 1 mbar ~ 1000 mbar | — |