Akım Sensörleri
- Komponent
- 2,744
- Marka
- 52
Komponentler
2,744 sonuç · Sayfa 27/55| Parça No | Üretici | Part Status | Operating Temperature | Mounting Type | Package / Case | Polarization | Frequency | Sensitivity | Number of Channels | Supplier Device Package | Response Time | Output | Voltage - Supply | Current - Supply (Max) | Accuracy | Sensor Type | Linearity | For Measuring | Current - Sensing | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CSCA0100A000B15B01
SENSOR CURRENT HALL 100A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 100A | — |
|
CSCA0100A000B15B02
SENSOR CURRENT HALL 100A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 100A | — |
|
CSCA0200A000B15B01
SENSOR CURRENT HALL 200A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 200A | — |
|
CSCA0200A000B15B02
SENSOR CURRENT HALL 200A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 200A | — |
|
CSCA0300A000B15B01
SENSOR CURRENT HALL 300A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 300A | — |
|
CSCA0300A000B15B02
SENSOR CURRENT HALL 300A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 300A | — |
|
CSCA0300A000B15B12
SENSOR CURRENT HALL |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
CSCA0400A000B15B01
SENSOR CURRENT HALL 400A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 400A | — |
|
CSCA0400A000B15B02
SENSOR CURRENT HALL 400A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 400A | — |
|
CSCA0400A000B15B12
SENSOR CURRENT HALL |
Honeywell Sensing and Productivity Solutions | Obsolete | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
CSCA0500A000B15B01
SENSOR CURRENT HALL 500A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 500A | — |
|
CSCA0500A000B15B02
SENSOR CURRENT HALL 500A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 500A | — |
|
CSCA0600A000B15B01
SENSOR CURRENT HALL 600A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 600A | — |
|
CSCA0600A000B15B02
SENSOR CURRENT HALL 600A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -10°C ~ 80°C | Chassis Mount | Module | Bidirectional | DC ~ 50kHz | — | 1 | — | 3µs | Ratiometric, Voltage | ±15V | 17mA | ±2% | Hall Effect, Open Loop | ±1% | AC/DC | 600A | — |
|
CSDA1AA
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 1A | — |
|
CSDA1AC
SENSOR CURRENT SWITCH 7.5A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 7.5A | — |
|
CSDA1BA
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 1A | — |
|
CSDA1BA-S
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 1A | — |
|
CSDA1BC
SENSOR CURRENT SWITCH 7.5A AC/DC |
WEC | Active | -25°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 7.5A | — |
|
CSDA1DA
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Connector | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 1A | — |
|
CSDA1DC
SENSOR CURRENT SWITCH 7.5A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 12mA | ±0.5% | Current Switch | — | AC/DC | 7.5A | — |
|
CSDB1CC
SENSOR CURRENT SWITCH 7.5A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -25°C ~ 85°C | Chassis Mount | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 6V ~ 16V | 16mA | — | Current Switch | — | AC/DC | 7.5A | — |
|
CSDC1AC
SENSOR CURRENT SWITCH 7.5A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 5V | 12mA | — | Current Switch | — | AC/DC | 7.5A | — |
|
CSDC1BA
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 5V | 12mA | — | Current Switch | — | AC/DC | 1A | — |
|
CSDC1DA
SENSOR CURRENT SWITCH 1A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | — | 1 | — | 100µs | NPN | 5V | 12mA | — | Current Switch | — | AC/DC | 1A | — |
|
CSDD1EC
SENSOR CURRENT SWITCH 5A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -25°C ~ 85°C | Through Hole | 5-DIP Module | Bidirectional | — | — | 1 | — | 100µs | NPN | 4.5V ~ 24V | 22mA | — | Current Switch | — | AC/DC | 5A | — |
|
CSDD1EG
SENSOR CURRENT SWITCH 10A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | 5-DIP Module | Bidirectional | — | — | 1 | — | 100µs | NPN | 4.5V ~ 24V | 22mA | — | Current Switch | — | AC/DC | 10A | — |
|
CSDD1FR
CURRENT SENSOR |
Honeywell Sensing and Productivity Solutions | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
CSLA1CD
SENSOR CURRENT HALL 57A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 49.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 57A | — |
|
CSLA1CE
SENSOR CURRENT HALL 75A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 39.4mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 75A | — |
|
CSLA1CF
SENSOR CURRENT HALL 100A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 29.7mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 100A | — |
|
CSLA1CH
SENSOR CURRENT HALL 150A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 19.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 150A | — |
|
CSLA1DE
SENSOR CURRENT HALL 75A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 39.1mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 75A | — |
|
CSLA1DG
SENSOR CURRENT HALL 120A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 24.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 120A | — |
|
CSLA1DJ
SENSOR CURRENT HALL 225A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 13.2mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 225A | — |
|
CSLA1DK
SENSOR CURRENT HALL 325A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 9.1mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 325A | — |
|
CSLA1EL
SENSOR CURRENT HALL 625A AC/DC |
WEC | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 5.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 625A | — |
|
CSLA1GD
SENSOR CURRENT HALL 57A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 49.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 57A | — |
|
CSLA1GE
SENSOR CURRENT HALL 75A AC/DC |
Honeywell Sensing and Productivity Solutions | Obsolete | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 39.4mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 75A | — |
|
CSLA1GF
SENSOR CURRENT HALL 100A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 29.7mV/N | 1 | — | 3µs | Ratiometric, Voltage | 8V ~ 16V | 19mA | — | Hall Effect, Open Loop | — | AC/DC | 100A | — |
|
CSLA2CD
SENSOR CURRENT HALL 72A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 32.7mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 72A | — |
|
CSLA2CDI
CURRENT SENSOR |
Honeywell Sensing and Productivity Solutions | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
CSLA2CE
SENSOR CURRENT HALL 62A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 26.1mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 92A | — |
|
CSLA2CEI
CURRENT SENSOR |
Honeywell Sensing and Productivity Solutions | Active | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
|
CSLA2CF
SENSOR CURRENT HALL 125A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 19.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 125A | — |
|
CSLA2CFI
SENSOR CURRENT HALL 125A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 19.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 125A | — |
|
CSLA2DE
SENSOR CURRENT HALL 92A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 25.6mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 92A | — |
|
CSLA2DG
SENSOR CURRENT HALL 150A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 16.2mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 150A | — |
|
CSLA2DGI
SENSOR CURRENT HALL 150A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 16.2mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 150A | — |
|
CSLA2DH
SENSOR CURRENT HALL 235A AC/DC |
Honeywell Sensing and Productivity Solutions | Active | -25°C ~ 85°C | Through Hole | Module, Single Pass Through | Bidirectional | — | 9.8mV/N | 1 | — | 3µs | Ratiometric, Voltage | 6V ~ 12V | 20mA | — | Hall Effect, Open Loop | — | AC/DC | 235A | — |